Correct evaluation of renal glomerular filtration rate requires clearance assays.
Iohexol clearance is an accepted, but time-consuming assay for the measurement of glomerular filtration rate (GFR). We investigated if simpler methods could predict GFR. Sixty-nine children with hematological-oncological disorders participated. A linear relationship was established by regression analysis between iohexol clearance ( n=734) and 1/s-creatinine ( r=0.45, n=727), s-cystatin C ( r=0.41,