Sökresultat

Filtyp

Din sökning på "*" gav 535600 sökträffar

Quantification and comparison of visibility and image artifacts of a new liquid fiducial marker in a lung phantom for image-guided radiation therapy

Purpose: A new biodegradable liquid fiducial marker was devised to allow for easy insertion in lung tumors using thin needles. The purpose of this study was to evaluate the visibility of the liquid fiducial markers for image-guided radiation therapy and compare to existing solid fiducial markers and to one existing liquid fiducial marker currently commercially available. Methods: Fiducial marker v

Dose escalation to high-risk sub-volumes based on non-invasive imaging of hypoxia and glycolytic activity in canine solid tumors : A feasibility study

Introduction: Glycolytic activity and hypoxia are associated with poor prognosis and radiation resistance. Including both the tumor uptake of 2-deoxy-2-[18 F]-fluorodeoxyglucose (FDG) and the proposed hypoxia tracer copper(II)diacetyl-bis(N4)-methylsemithio-carbazone (Cu-ATSM) in targeted therapy planning may therefore lead to improved tumor control. In this study we analyzed the overlap between s

The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery

Purpose: Real-time dynamic multileaf collimator (MLC) tracking for management of intrafraction tumor motion can be challenging for highly modulated beams, as the leaves need to travel far to adjust for target motion perpendicular to the leaf travel direction. The plan modulation can be reduced by using a leaf position constraint (LPC) that reduces the difference in the position of adjacent MLC lea

The MCNP Monte Carlo Program

Monte Carlo N-Particle (MCNP) is a Monte Carlo code package allowing coupled neutron, photon, and electron transport calculations. Also, the possibility of performing heavy charged particle transport calculations was recently introduced with the twin MCNPX code package. An arbitrary three-dimensional problem can be formulated through the use of surfaces defining building blocks (“cells” that are a

Patient QA systems for rotational radiation therapy : A comparative experimental study with intentional errors

Purpose: The purpose of the present study was to investigate the ability of commercial patient quality assurance (QA) systems to detect linear accelerator-related errors. Methods: Four measuring systems (Delta 4®, OCTAVIUS®, COMPASS, and Epiqa™) designed for patient specific quality assurance for rotational radiation therapy were compared by measuring four clinical rotational intensity modulated r

Long term safety and visibility of a novel liquid fiducial marker for use in image guided radiotherapy of non-small cell lung cancer

Safety and clinical feasibility of injecting a novel liquid fiducial marker for use in image guided radiotherapy in 15 patients with non-small cell lung cancer are reported. No major safety or toxicity issues were encountered. Markers present at start of radiotherapy remained visible in cone beam computed tomography and fluoroscopy images throughout the treatment course and on computed tomography

The clinical commissioning of beams for neutron capture therapy

The clinical commissioning of beams for neutron capture therapy involves the measurement and analysis of a large amount of data in various geometries and using various detectors. The process as such is akin to that in the conventional photon and electron radiotherapy field, while the tools, methods and considerations in the field of neutron capture therapy are different. This chapter provides an i

A treatment planning study of the potential of geometrical tracking for intensity modulated proton therapy of lung cancer

Background. Proton therapy of lung cancer holds the potential for a reduction of the volume of irradiated normal lung tissue. In this work we investigate the robustness of intensity modulated proton therapy (IMPT) plans to motion, and evaluate a geometrical tumour tracking method to compensate for tumour motion. Material and methods. Seven patients with a nine targets with 4DCT scans were selected

Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes

The introduction of integrated MRI-radiation therapy systems will offer live intra-fraction imaging. We propose a feasible low-latency multi-plane MRI-linac guidance strategy. In this work we demonstrate how interleaved acquired, orthogonal cine-MRI planes can be used for low-latency tracking of the 3D trajectory of a soft-tissue target structure. The proposed strategy relies on acquiring a pre-tr

Deviations in delineated GTV caused by artefacts in 4DCT

Background and purpose: Four-dimensional computed tomography (4DCT) is used for breathing-adapted radiotherapy planning. Irregular breathing, large tumour motion or interpolation of images can cause artefacts in the 4DCT. This study evaluates the impact of artefacts on gross tumour volume (GTV) size. Material and methods: In 19 4DCT scans of patients with peripheral lung tumours, GTV was delineate

Injectable colloidal gold for use in intrafractional 2D image-guided radiation therapy

In the western world, approximately 50% of all cancer patients receive radiotherapy alone or in combination with surgery or chemotherapy. Image-guided radiotherapy (IGRT) has in recent years been introduced to enhance precision of the delivery of radiation dose to tumor tissue. Fiducial markers are often inserted inside the tumor to improve IGRT precision and to enable monitoring of the tumor posi

Interobserver delineation variation in lung tumour stereotactic body radiotherapy

Objectives: In radiotherapy, delineation uncertainties are important as they contribute to systematic errors and can lead to geographical miss of the target. For margin computation, standard deviations (SDs) of all uncertainties must be included as SDs. The aim of this study was to quantify the interobserver delineation variation for stereotactic body radiotherapy (SBRT) of peripheral lung tumours

Long-term prevention of bladder cancer progression by alpha1-oleate alone or in combination with chemotherapy

Bladder cancer is common and one of the most costly cancer forms, due to a lack of curative therapies. Recently, clinical safety and efficacy of the alpha1-oleate complex was demonstrated in a placebo-controlled study of nonmuscle invasive bladder cancer. Our study investigated if long-term therapeutic efficacy is improved by repeated treatment cycles and by combining alpha1-oleate with low-dose c

Plasma p-tau181 and p-tau217 in discriminating PART, AD and other key neuropathologies in older adults

We examined whether plasma p-tau181 and p-tau217 are specific biomarkers of pathologically confirmed Alzheimer’s disease (AD). In particular, we investigated the utility of plasma p-tau for differentiating AD from primary age-related tauopathy (PART), as well as AD with mixed pathologies. Data came from 269 older adults who participated in the Religious Orders Study or the Rush Memory and Aging Pr

Discriminative accuracy of the A/T/N scheme to identify cognitive impairment due to Alzheimer's disease

Introduction: The optimal combination of amyloid-β/tau/neurodegeneration (A/T/N) biomarker profiles for the diagnosis of Alzheimer's disease (AD) dementia is unclear. Methods: We examined the discriminative accuracy of A/T/N combinations assessed with neuroimaging biomarkers for the differentiation of AD from cognitively unimpaired (CU) elderly and non-AD neurodegenerative diseases in the TRIAD, B

Critical factors for involvement in customers’ product development : an SME perspective

Purpose: This paper aims to identify critical factors that influence small and medium-sized enterprise (SME) suppliers’ involvement in their customers’ product development and contrast these with the factors identified from the customer perspective. Design/methodology/approach: A multiple case study approach was used, including four companies. Data were collected through 32 semi-structured intervi

Impact of atmospheric pressure variations on aerobic biodegradation test

Biodegradation rate is an important index to evaluate the environmental risk of chemicals, which is usually determined by measuring oxygen consumption through respirometer in a biodegradation test. However, atmospheric pressure variations affect reactor oxygen concentration and oxygen volume recorded by respirometer in biodegradation test, and the parameters of reactor volume and test material amo